機(jī)型:50E690U
機(jī)芯:9R10
故障現(xiàn)象:黑屏、打印信息自動(dòng)重啟
分析檢修:該系列主板出現(xiàn)黑屏的現(xiàn)象較多,一般升級(jí)主程序即可解決,但在升級(jí)之前需要先查看下屏參是否異常,主要打印信息如下:
------------tmp/factory/layout.txt found
BOOTPART=0
TAG=21
init_amp
Panel: Use parameters in tmp/factory/bin_panel/panel.bin
Panel: inx_in8922_65_4K2k_vby1
panel_init_1st
raise: Signal # 8 caught
raise: Signal # 8 caught
Panel: ulFreq:148500000, nDPLL:157499520, Mcode:35, Ncode:3, offset:751
================== P_VBY1_4K2K condition ===================
***** Get Chip ID (3) *****
==================VBY_ONE_PANEL_INX8922_4K2K_VBY1===================
DispI : Finish BISR testing done
DispD : Finish BISR testing done
Panel_Custom_INDEX=5
========= INX_8922_2k1k_script ==========
In: serial
Out: serial
Err: serial
Net: rtl8139: REALTEK RTL8139 @0xb8016000
Hit Esc or Tab key to enter console mode or rescue linux: 0
------------bootloader message size is 1088
abortboot main.c 380 -- (0)
abortboot main.c 380 -- (1)
abortboot main.c 380 -- (2)
abortboot main.c 380 -- (3)
abortboot main.c 380 -- (4)
Press Esc Key
Enter console mode, disable watchdog ...
Realtek>
從上面的紅色部分我們可以看出該主板的屏參是配65”屏,因此需要先將屏參改成50”,然后升級(jí)主程序后開(kāi)機(jī)圖像正常。
總結(jié):出現(xiàn)自動(dòng)重啟的問(wèn)題時(shí)有可能是主板與屏TOCN板之間通信失敗造成的,因?yàn)椴煌钠?a href="http://ktgpgw.cn/bbs-37-1.html" target="_blank" class="relatedlink">軟件設(shè)置不一樣,有些屏的軟件需要檢測(cè)TOCN板的通信,如果出現(xiàn)自動(dòng)重啟的問(wèn)題時(shí)可以嘗試將屏參改成50”的屏在升級(jí)主程序試試問(wèn)題是否解決。
|
上一篇: 創(chuàng)維49E710U不開(kāi)機(jī)解決方案下一篇: 創(chuàng)維液晶電視5800-A8DA22-0020主板維修圖解說(shuō)明
|